Product Description
Eppendorf centrifuges 5810 and 5810 R with their renowned quality and reliability offer you the most cost efficient solutions for your medium to high-throughput applications—now and in the future. Whether your applications require spinning many tubes at a time or centrifugation of larger volume vessels at high-speed, these multipurpose centrifuges with their variety of rotors and adapters cover virtually any application in tubes, bottles, flasks and microplates. They are literally three centrifuges in one: a high-capacity centrifuge for cell culture and clinical applications; a high-speed centrifuge for separating cell lysates; and a microcentrifuge for nucleic acid purification.
More Info
Features
- Outstanding versatility for all your applications: Broad rotor and adapter selection to spin all commonly used tubes, bottles, flasks and plates
- High centrifugation speed up to 20,800 x g (14,000 rpm) for molecular applications in tubes from 0.2 to 750 mL
- Aerosol-tight rotors and covers for all centrifuge applications involving hazardous materials (pathogenic bacteria, viruses, blood samples or radioactive material)
- The benchmark for ergonomic operation: Low sound level to benefit your work environment
- Low profile design for ergonomic loading/unloading of rotor
- Advanced rotor design minimizes fixed-angle rotor weight for easy lifting and carrying
- Automatic rotor recognition and imbalance detection for maximum operational safety
- Centrifuge performance you can count on: Outstanding software control guarantees high accuracy of time (±2 s in 5 min), speed (1% ) and temperature (±2°C at 6°C ) for maximum run reproducibility
- Temperature range from –9°C to 40°C , with FastTemp function for rapid cooling of the centrifuge chamber
- Standby cooling maintains temperature when not in use
More Features
| Centrifuge 5810 | Centrifuge 5810 R | Centrifuge 5810 R, 20 A | |
|---|---|---|---|
| Max g-force | 20,800 rcf | 20,800 rcf | 20,800 rcf |
| Speed range | 200-14,000 rpm | 200-14,000 rpm | 200-14,000 rpm |
| Capacity | 4 x 750 mL (SB), 6 x 100 mL (F), 4 x DWP | 4 x 750 mL (SB), 6 x 100 mL (F), 4 x DWP | 4 x 750 mL (SB), 6 x 100 mL (F), 4 x DWP |
| Number of rotors | 18 | 18 | 18 |
| Capacity for 1.5 mL tubes |
248 | 248 | 248 |
| Capacity for 50 mL conical tubes |
28 | 28 | 28 |
| Capacity for PCR plates |
16 | 16 | 16 |
| Refrigeration | No | Yes | Yes |
| Temperature control range |
N/A | -9°C to 40°C | -9°C to 40°C |
| Power supply | 120 V, 50/60 Hz | 120 V, 50/60 Hz | 120 V, 50/60 Hz |
| Required current | Standard 15 Amp | Standard 15 Amp | 20 Amp |
| Power consumption | max. 950 W | max. 1300 W | max. 1650 W |
| Acceleration time to max speed |
Depends on rotor and ramp speed | Depends on rotor and ramp speed | Depends on rotor and ramp speed |
| Braking time from max speed |
Depends on rotor and ramp speed | Depends on rotor and ramp speed | Depends on rotor and ramp speed |
| Timer | 1 to 99 min, with cont. mode | 1 to 99 min, with cont. mode | 1 to 99 min, with cont. mode |
| Noise level | <53 dB(A) | <59 dB(A) | <59 dB(A) |
| Dimensions (W x D x H) |
21 x 21 x 13 in / 54 x 54 x 35 cm | 28 x 21 x 13 in / 70 x 54 x 35 cm | 28 x 21 x 13 in / 70 x 54 x 35 cm |
| Height with lid open | 31 in / 80 cm | 31 in / 80 cm | 31 in / 80 cm |
| Weight | 150 lb / 68 kg | 218 lb / 99 kg | 218 lb / 99 kg |
Brochures
| Name | Language | Document type | Size | Download |
|---|---|---|---|---|
|
Flyer Centrifuge 58XX family Reliable Performance |
English (US) | 1.67 MB | download | |
|
Book Centrifuges Centrifugation Guide |
English (US) | 216.28 kB | download | |
|
Insert Centrifuge 58XX family Insert LabTimes Pe INTERNAL |
English (US) | 4.54 MB | download | |
|
Brochure Centrifuge 58XX family Reliable Performance |
English (US) | 9.46 MB | download |
Manuals
| Name | Language | Document type | Size | Download |
|---|---|---|---|---|
|
Operating manual Centrifuge 58XX family Centrifuge 5804 58 |
English (US) | 8.45 MB | download | |
|
Instructions for use Cell culture bottle adapter Cell culture bottle |
English (US) | 317.9 kB | download | |
|
Instructions for use Centrifuges Aerosol tight centri |
English (US) | 66.26 kB | download | |
|
Instructions for use Centrifuge 58XX family 5430 family Instructions for loa |
English (US) | 217.96 kB | download | |
|
Leaflet Centrifuge 5804 family 5810 family How to close aerosol |
English (US) | 257.29 kB | download | |
|
Leaflet Centrifuges Supplement sheet E |
English (US) | 116.16 kB | download |
FAQs
How are the Centrifuges 5804/ 5804 R and 5810/ 5810 R protected during transport? Is there a transport protection device?No, the Centrifuges 5804/ 5804 R and 5810/ 5810 R do not come with a transport protection device. They are packaged in polystyrene for protection. Because the rotor is not in the centrifuge during transport, there are no movable parts to make a transport protection device necessary.
Can I still change the settings when I have started the Centrifuges 5804/ 5804 R or 5810/ 5810 R?Yes, the speed, the time and the temperature can be changed even when the centrifuge is running. To do this, please press the SPEED, TIME or TEMP key and change the values by pressing the arrow keys.
How can I recognize in the display of the Centrifuges 5804/ 5804 R or 5810/ 5810 R whether I have selected "rpm" or "rcf"?For rcf, a "*" is displayed in front of the value. rpm is not indicated by a symbol.
What is the minimum rotational speed (rpm) of the Centrifuge 5804/ 5804 R or 5810/ 5810 R, and in which increments can it be increased?The minimum rotational speed is 200 rpm, irrespective of the inserted rotor. The minimum rotational speed can be increased in increments of 10 rpm up to 5,000 rpm and then in increments of 100 rpm.
Is it possible to adjust the Centrifuge 5804/ 5804 R or 5810/ 5810 R so that it stops on its own, meaning without active braking?Yes. Free deceleration of your centrifuge can be achieved by setting the braking level to 0.
"Clean rotor" appears on the display of my centrifuge. Do I now need to remove the rotor from the centrifuge, and, if yes, how?This display appears every 200 centrifugation runs. For cleaning the rotor and the rotor chamber, the rotor must first be removed from the centrifuge. To do this, loosen the rotor nut by turning it counter-clockwise with the supplied rotor key. Please clean the rotor and rotor chamber only with mild cleaning agents (e.g. 70% alcohol solutions or commercially available alcoholic disinfectants).
The Centrifuges 5804/ 5804 R and 5810/ 5810 R are programmable. What is saved during the programming?All data is saved that can also be entered manually, such as rotational speed or RCF, maximum radius, run time, acceleration and braking ramps, "at set rpm", temperature.
Is it possible to centrifuge 50 mL and 15 mL tubes together in one rotor?Yes, it is possible, provided that the rotor is loaded symmetrically. This means that the 50 mL tubes and the 15 mL tubes are positioned opposite one another and are positioned symmetrically. Please use the appropriate adapters for the tubes.
Does Eppendorf offer a rotor for PCR strips for Centrifuges 5804/ 5804 R or 5810/ 5810 R?The PCR strip rotor F-45-48-PCR is available under the order number 5804 735.005. It can centrifuge up to 6 x 8-well strips at 12,000 rpm / 15,350 x g.
In which rotor is it possible to centrifuge 50 mL DIN glass tubes?50 mL DIN glass tubes (diameter 34 mm, length 100 mm) can be centrifuged in the adapter for 50 - 75 ml tubes (order number 5804 760.000) of the swing-bucket rotor A-4-44. Depending on the length of the tube, the uppermost module of the adapter can be removed for centrifugation of 50 mL DIN glass tubes.
Millipore offers centrifugation filter tubes (Centripreps). Can these tubes be centrifuged in a rotor of the Centrifuge 5804/5804 R or 5810/5810 R?Yes, for 50 ml Centripreps we offer the adapter 5810 739.004 for the rotor A-4-81.
Into which rotor of the Centrifuge 5804/5804 R or 5810/5810 R do 15 ml and 30 ml Corex tubes fit?With a rubber adapter (outer diameter 18 mm) available from the tube manufacturer, the 15 ml Corex tubes fit into the adapter 5804 772.008 of the rotor F-34-6-38. With a rubber adapter (outer diameter 29 mm) available from the tube manufacturer, the 30 ml Corex tubes fit into the adapter 5804 774.000 of the rotor F-34-6-38. This rotor can be inserted into the Centrifuge 5804/5804 R or 5810/5810 R.
How big is the g-force difference between the lowest and the highest plate when loading a bucket of the rotor A-2-DWP with four microplates?The following g-forces are reached with the rotor A-2-DWP: Lowest plate: 2,250 x g Highest plate: 1,825 x g
Is there an adapter for slides?Up to 12 slides can be inserted into the CombiSlide adapter and then centrifuged in the swing-bucket rotors of Centrifuge 5804/ 5804 R or 5810/ 5810 R.
Does the Centrifuge 58xx R has an energy saving function?Yes, the ECO shut-off automatically switchs off the compressor after 8 hours of non-use. The device has a stand-by button.
What is the meaning of the red knob on the rotor lid?A fixed-angle rotor with a red knob on the rotor lid indicates aerosol-tightness.