Quick Links
| Certificates | Sample Request |
Product Description
More Info
Features
- DNA LoBind for DNA or RNA applications in forensic analysis, microarrays, next generation sequencing
- LoBind material guarantees maximum sample recovery for improved assay results
- Free of surface coating (e.g. siliconization) to eliminate the risk of sample interference
- Certified free of DNA, DNase, RNase and PCR inhibitors (PCR clean)
Tubes feature:
- Hinged Safe-Lock lid prevents accidental lid opening during incubation
- Precise lid sealing for lowest evaporation rates during long-term storage
- Rated up to 30,000 x g centrifugation speed for molecular biology applications
Plates feature:
- OptiTrack® labeling: 30% faster well identification and less pipetting errors due to colored border with high contrast alphanumeric labeling
- RecoverMax® conical well-design: Optimized well geometry for maximum sample recovery and excellent mixing performance. The smooth contours also reduce capillary effects in well corners (“wicking”), minimizing the risk of cross-contamination.
- Raised well rims and even surface for reliable sealing
More Features
| 0.5 mL tube | 1.5 mL tube | 2.0 mL tube | Deepwell plate 96/1000 | Deepwell plate 96/500 | Deepwell plate 384/200 | Microplate 384/V | |
|---|---|---|---|---|---|---|---|
| Tube, deepwell plate or microplate |
Tube | Tube | Tube | Deepwell | Deepwell | Deepwell | Microplate |
| Max. volume | 500 µL | 1,500 µL | 2,000 µL | 1,200 µL | 700 µL | 240 µL | 140 µL |
| Bottom shape | Conical | Conical | Round | RecoverMax conical | RecoverMax conical | RecoverMax conical | RecoverMax conical |
| g-force rating | 30,000 x g | 30,000 x g | 25,000 x g | 30,000 x g | 30,000 x g | 30,000 x g | 6,000 x g |
| Plastic materials | Polypropylene | Polypropylene | Polypropylene | Polypropylene | Polypropylene | Polypropylene | Polypropylene |
| Purity | PCR clean | PCR clean | PCR clean | PCR clean | PCR clean | PCR clean | PCR clean |
| Free from human DNA | Yes | Yes | Yes | Yes | Yes | Yes | Yes |
| Free from bacteria DNA |
Not tested | Not tested | Not tested | Not tested | Not tested | Not tested | Not tested |
| DNase-free | Yes | Yes | Yes | Yes | Yes | Yes | Yes |
| RNase-free | Yes | Yes | Yes | Yes | Yes | Yes | Yes |
| Free from PCR inhibitors |
Yes | Yes | Yes | Yes | Yes | Yes | Yes |
| ATP-free | Not tested | Not tested | Not tested | Not tested | Not tested | Not tested | Not tested |
| Pyrogen (endotoxin)-free |
Not tested | Not tested | Not tested | Not tested | Not tested | Not tested | Not tested |
| Sterile | No | No | No | No | No | No | No |
| Dimensions (W x D x H) |
5.03 x 3.37 x 1.74 in/127.8 x 85.5 x 44.1 mm | 5.03 x 3.37 x 1.07 in/127.8 x 85.5 x 27.1 mm | 5.03 x 3.37 x 0.99 in/127.8 x 85.5 x 25.1 mm | 5.03 x 3.37 x 0.57 in/127.8 x 85.5 x 14.4 mm |
Applications
| Name | Language | Document type | Size | Download |
|---|---|---|---|---|
|
Application 226 LoBind Tubes Use of Eppendorf LoB |
English (US) | 232.79 kB | download | |
|
Application 180 LoBind Tubes Deepwell Plates Eppendorf LoBind E |
English (US) | 1.79 MB | download |
Brochures
| Name | Language | Document type | Size | Download |
|---|---|---|---|---|
|
Flyer Tips Tubes Plates Make the right choic Example for invitation. |
English (US) | 119.52 kB | download | |
|
Brochure Consumables Absolute Certainty |
English (US) | 4.41 MB | download | |
|
Flyer Consumables So Pure Purity gr |
English (US) | 222.8 kB | download | |
|
Brochure LoBind Tubes and Plates Now you have it all |
English (US) | 276.29 kB | download | |
|
Flyer Consumables Eppendorf Purity Gra |
English (US) | 947.06 kB | download |
Manuals
| Name | Language | Document type | Size | Download |
|---|---|---|---|---|
|
Operating manual LoBind Tubes Eppendorf LoBind Tub |
English (US) | 319.46 kB | download |
FAQs
What distinguishes the DNA LoBind Tube from a "Standard" Safe-Lock Tube?In comparison to a Safe-Lock Tube, the DNA LoBind Tube shows significantly less DNA bonding affinity. This effect is most apparent with high salt concentrations and when working with short DNA fragments. The DNA LoBind Tube is therefore especially suitable for applications that should be carried out with the minimum loss of nucleic acid material.
Do the Eppendorf LoBind Tubes have the same material durability as all other micro test tubes from Eppendorf?The Eppendorf LoBind Tubes completely satisfy the specifications of the Eppendorf Standard Safe Lock tubes with reference to centrifugation stability (exception: Protein LoBind Tube), lid tightness, pop up safety and chemical resistance. (See Application No. 56: The best material for original Eppis.)
Are the Eppendorf LoBind Tubes coated?Not the Eppendorf LoBind Tubes are neither siliconized nor coated. The low binding affinity results from of a special type of polypropylene and the optimized manucturing process.
What is the life expectancy of Eppendorf micro test tubes?At least 5 years at a storage temperature of +5 to +35 °C.
From what material are your micro test tubes manufactured?All of our tubes are manufactured from polypropylene. The polypropylene we use fulfils the specifications of the FDA for the use of plastics for foodstuffs. No metal-based dyes are used.
Do you offer siliconized micro test tubes?Our tube assortment does not include coated or siliconized tubes. In order to keep sample loss caused by the adsorption of sample material on the tube wall to a minimum, we recommend using the Eppendorf Protein LoBind Tubes or Eppendorf DNA LoBind Tubes. These are made of a special type of polypropylene and are manufactured under optimized process conditions.
Is there a chemical resistance overview for the individual micro test tube types?Yes. The Eppendorf Application No. 56 "The best material for original eppis!" includes among other things a detailed material stability overview.
Can Eppendorf micro test tubes be sterilized with ethylene oxide?Yes, this is possible. Please note that the micro test tubes have to be taken out of the packaging for sterilization. In addition, please note that some ethylene oxide will remain in the material after sterilization.
Can your micro test tubes be frozen at -80 °C?Yes. Please refer to the operating manual.
Can your micro test tubes be coated with acrylic resin within the framework of a UV polymerization?Yes, the tubes can withstand UV polymerization. However, we cannot give you any instructions for the procedure.
Can contamination of micro test tubes by bacterial endotoxin be inactivated by autoclaving?No. Bacterial endotoxins (lipopolysaccharide, LPS) are very stable and withstand normal autoclaving at 121 °C. To inactivate LPS, the objects have to be baked at 250 °C, which, of course, is not possible with plastics.
Are the Eppendorf micro test tubes anti-static?Our tubes are not produced from antistatic material, i.e. they are basically not antistatic. But it should be noted that the use of antistatic agents during production will destroy or reduce the wettability of the tubes.
Which Eppendorf micro test tubes are free of DNA?All micro test tubes designated with "PCR clean" are free of human DNA, DNase, RNase and PCR inhibitors. Our Safe-Lock micro test tubes are also available in the "Eppendorf Biopur" purity standard. Due to the special manufacturing processes and the individual blister-packaging, Biopur products are certified "DNA free".
What level of protein binding affinity do your micro test tubes demonstrate?Our micro test tubes are used both in the proteomics area and for storage and transport of many different protein solutions. If you work with low protein concentrations, we recommend using the Eppendorf Protein LoBind Tubes. These tubes are made of a special type of polypropylene and are manufactured under optimized process conditions. In comparison to standard polypropylene tubes, these tubes therefore demonstrate a considerably lower affinity to proteins.
How do you define the temperature entry "RT", for example, as a storage condition for your micro test tubes?Definition of RT (room temperature): +5 to +35 °C.
What is the best way to label Eppendorf micro test tubes?The micro test tube should be clean and free from grease and only labeled on the space provided. Water-resistant felt pens from Steadtler S and F, in black, are the most suitable for this. The writing should be left to dry for at least 2 min.
Do your micro test tubes contain heavy metals?Lead, cadmium, mercury, etc. are well below the prescribed limits of the DIN norm. In the course of the production process it is impossible to avoid the smallest quantities of metal resulting from machine friction.
Overview regarding the centrifugation resistance of Eppendorf tubesSafe-Lock 0.5 ml: 30,000 x g / Biopur 22,000 x g / DNA LoBind 30,000 x g / Protein LoBind 18,000 x g
Safe-Lock 1.5 ml: 30,000 x g / Biopur 22,000 x g / DNA LoBind 30,000 x g / Protein LoBind 18,000 x g
Safe-Lock 2.0 ml: 25,000 x g / Biopur 22,000 x g / DNA LoBind 25,000 x g / Protein LoBind 18,000 x g
3810X: 30,000 x g
3810: 25,000 x g
When using form-fitting tubes and buckets and filling the tubes with their nominal volume, centrifugation of the Safe-Lock Tubes at 25 °C for 30 min at up to 70,000 x g (RT) is possible.
Tubes can be centrifuged in a 45°-fixed-angle rotor at 40 °C sample temperature and 90 min with aqueous saline solution (density 1.0 g/ml) up to the above g-forces. The centrifugation resistance depends on the temperature and will be lower at sample temperatures of
Are the Eppendorf tubes autoclavable?Yes, all Eppendorf tubes are autoclavable when open (20 min, 121 °C, 1 bar).